Bearing SelectorPick the right bearing, step by stepVerify a BearingLife, safety factor and fitsLoad CalculatorLoads from your machineWorked templatesFan, gear and shaft load templatesCross-ReferenceNewSame size from other makers. Free, no sign-upBearing AutopsyNewUpload a photo, get the likely causesFailure AnalysisRead damage, find the causeCondition MonitoringVibration, envelope, oil clues, RCMLubricationGreases, oils, cleanliness, oil lifeEquipment AnatomyMotors, pumps, fans, gearboxesFAQ and quick checksSearch the basics in plain languageFind a DistributorSuppliers by brand and city

Learn

Free calculatorsLife, grease, oil, loads and moreFind a bearingSize, rating and equivalents by designationFailure modesDamage types, causes and fixesCondition monitoringVibration, envelope, oil clues, RCMKnowledge libraryLubrication and reliability articlesBearings by machineMotors, pumps, mills, kilns and moreHow-to guidesBearing life, grease, failures, numbersShaft alignmentSoft foot, procedure, tolerances, heatField casesFailure investigations and monitoring cases (licence)Lubrication guidesGreases, oil systems, oil life and costQuick answersPlain-language answers to common questions

More

PricingPartnershipsContact
Pumps and energy

Worked example: an oversized pump throttled back, and what it costs

Quick answer

A pump with an impeller that is too big, held in check by a valve, uses about twice the power of the right impeller. Work through the numbers step by step.

By Tanmay Sharma, founder of Rotec AI · Last reviewed 6 November 2026

The situation

The duty is 68 m3/h at 47 m head. The pump has a large impeller (call it A) that makes 76 m head at this flow, so the discharge valve is throttled to hold 68 m3/h. A smaller impeller (call it E) would meet the duty with no throttling. The figures below are an illustrative calculation, not a field measurement.

Power with each impeller

ItemRight impeller (E)Large impeller, throttled (A)
Flow68 m3/h68 m3/h
Head the pump makes47 m76 m
Pump efficiency at that point60%50%
Hydraulic power8.7 kW14.1 kW
Shaft power14.5 kW28.2 kW
Electrical input at 90% motor efficiency16.1 kW31.3 kW

The cost of throttling

The difference is about 15 kW, running all the time. Over 8760 hours that is about 133,000 kWh a year. At an assumed tariff of Rs 4 per kWh, the extra cost is about Rs 5.3 lakh a year. In this example the yearly extra electricity cost is larger than the price of a new, correctly sized pump.

Why it is so costly

How to use this on your own pump

Takeaway. A throttled valve is a sign of wasted energy. Put a number on it: the difference in power times the running hours times the tariff.
Put it to work in the tool