Bearing SelectorPick the right bearing, step by stepVerify a BearingLife, safety factor and fitsLoad CalculatorLoads from your machineWorked templatesFan, gear and shaft load templatesCross-ReferenceNewSame size from other makers. Free, no sign-upBearing AutopsyNewUpload a photo, get the likely causesFailure AnalysisRead damage, find the causeCondition MonitoringVibration, envelope, oil clues, RCMLubricationGreases, oils, cleanliness, oil lifeEquipment AnatomyMotors, pumps, fans, gearboxesFAQ and quick checksSearch the basics in plain languageFind a DistributorSuppliers by brand and city

Learn

Free calculatorsLife, grease, oil, loads and moreFind a bearingSize, rating and equivalents by designationFailure modesDamage types, causes and fixesCondition monitoringVibration, envelope, oil clues, RCMKnowledge libraryLubrication and reliability articlesBearings by machineMotors, pumps, mills, kilns and moreHow-to guidesBearing life, grease, failures, numbersShaft alignmentSoft foot, procedure, tolerances, heatField casesFailure investigations and monitoring cases (licence)Lubrication guidesGreases, oil systems, oil life and costQuick answersPlain-language answers to common questions

More

PricingPartnershipsContact
Condition monitoring

Soft foot and the dynamic soft foot test

Quick answer

Soft foot twists a motor frame when the bolts are tightened. It shows as high directional vibration near 2 times line frequency. A running test, loosening one bolt at a time, finds the foot and gives a before-and-after number.

By Tanmay Sharma, founder of Rotec AI · Last reviewed 6 November 2026

What soft foot is

Soft foot is when one or more feet of a machine do not sit flat on the base. Tightening the bolts then pulls the frame out of shape. In a motor, that distorts the stator, changes the air gap and loads the bearings unevenly. It also shifts the shaft, so an alignment done before the soft foot was corrected is wrong.

Types

TypeWhat is wrongHow it shows
ParallelOne foot is too short or too longA rocking gap under the foot
AngularThe foot surface or base is not parallelA wedge-shaped gap
InducedPipe strain, a bent frame or a base that is not flatThe gap changes as the pipes are connected
SpringDirt, paint or a corroded shim under a footThe gap closes and opens as you tighten

What the spectrum may show

A common sign is elevated directional vibration, often more noticeable horizontally. In a 2-pole motor, 2X running speed is the same as 2 times line frequency, and in a 4-pole motor 4X running speed is. On a 50 Hz supply both lines fall at about 100 Hz. Mechanical and electrical causes overlap, so a dynamic soft foot test helps separate them.

The dynamic soft foot test

A real result

On one motor, loosening a single bolt dropped the reading from 6.2 mm/s RMS to 1.2 mm/s RMS. That is more than a fivefold fall from a single bolt.

After finding it

Takeaway. Elevated vibration near 100 Hz on a motor deserves a soft foot test before any electrical diagnosis.