Bearing SelectorPick the right bearing, step by stepVerify a BearingLife, safety factor and fitsLoad CalculatorLoads from your machineWorked templatesFan, gear and shaft load templatesCross-ReferenceSame size from other makersBearing AutopsyNewUpload a photo, get the likely causesFailure AnalysisRead damage, find the causeLubricationGreases, oils, cleanliness, oil lifeEquipment AnatomyMotors, pumps, fans, gearboxesFAQ and quick checksSearch the basics in plain languageFind a DistributorSuppliers by brand and city

Learn

Free calculatorsLife, grease, oil, loads and moreFind a bearingSize, rating and equivalents by designationFailure modesDamage types, causes and fixesKnowledge libraryLubrication and reliability articlesBearings by machineMotors, pumps, mills, kilns and moreHow-to guidesBearing life, grease, failures, numbersField casesFailure investigations and monitoring cases (licence)Lubrication guidesGreases, oil systems, oil life and costQuick answersPlain-language answers to common questions

More

PricingPartnershipsContact
Oil analysis

FTIR oil analysis: what it detects and where it can mislead

Infrared spectra give a fast screening of oil condition: water, oxidation, nitration, soot, glycol, additive depletion. Know the limits before trusting a single number.

What FTIR measures

Infrared light is absorbed by the chemical bonds of molecules, not by atoms, so the spectrum is a fingerprint of the chemistry of the oil. One scan of a thin film of oil can report several things at once: water, glycol, soot, oxidation, nitration, sulphation, additive level and contamination with other oils. It needs little sample preparation and has a low cost per test once the instrument is bought. It tells you about the molecules, so it complements elemental analysis (wear metals) rather than replacing it.

Qualitative and quantitative

Qualitative use compares peaks with a reference: better or worse. Quantitative use calibrates absorbance against known concentrations to give ppm or percent. Some results are semi-quantitative because calibration samples are hard to obtain, soot particle size varies, and fuel composition changes between locations.

Practical pointWhy it matters
Use a standard sample cell path (100 micrometre for the standard method)Different path lengths change the absorbance and the range
Filter and shake the sampleLarge particles scatter the beam and the sample must be representative
Subtract the new oil spectrumRemoves base oil and additive peaks so contaminants and degradation stand out
Keep the right referenceBatch changes, top-ups and a different brand make the reference invalid
Watch interferencesWater and glycol absorb in the same region and can mask each other

Standards

Practice standards for FTIR trend analysis and for oxidation, nitration, phosphate anti-wear and sulphation by FTIR exist in the ASTM family. Using them makes results comparable between instruments and laboratories.

When to use it

Use FTIR as a screening tool to find samples that need further work: viscosity, water content by a dedicated method, elemental analysis or particle counts. It is also useful for spotting an unplanned mix of oil types, such as a polyol ester oil mixed with a synthetic hydrocarbon oil.

Takeaway. FTIR is a quick screen. A change in the trend is a reason to look closer, not a verdict on its own.